Standard BMO permit conditions

15 min read

In consultation with local councils, CFA has developed standard Bushfire Management Overlay (BMO) permit conditions that prescribe the bushfire protection measures that must generally be implemented for development or subdivision in the BMO. The standard BMO conditions streamline the planning process and provide guidance for both councils and applicants. They strongly align with bushfire planning requirements and the bushfire protection measures required under the planning scheme. Learn more about the standard BMO permit conditions on this page.

Summary

  • CFA has created a set of standard conditions for bushfire protection measures applied to development applications under the BMO.
  • The standard permit conditions are a starting point or baseline for applicants preparing a permit application under the BMO.
  • Requirements can be tailored to an individual site, with CFA's written approval.
  • CFA will sometimes specify modified conditions when giving conditional approval of a permit application.

Standard BMO conditions provide a baseline

CFA has developed standard Bushfire Management Overlay (BMO) permit conditions in consultation with the Municipal Association of Victoria (MAV) and local councils, to assist with the processing of permit applications in the BMO.

The standard conditions prescribe the bushfire protection measures which are likely to be applied to most developments under the BMO, providing a baseline for BMO requirements. They include:

  • Construction standard
  • Defendable space
  • Water supply
  • Vehicle access

In many instances, CFA’s standard BMO conditions, including those relating to water supply, access and defendable space, mirror requirements in the planning scheme. This provides more certainty for permit applicants with regard to bushfire protection measures.

Standard planning permit conditions

The following standard conditions are provided as a baseline for BMO requirements and can be used as a guide for decision makers when assessing applications. They must not be changed unless agreed in writing by CFA.

How the standard permit conditions are used

The standard BMO permit conditions strongly align with bushfire planning requirements and the bushfire protection measures required under the planning scheme.

They are often used as a starting point for councils when assessing what requirements should be applied to any given application. However, they may change based on the merits of the application and its individual characteristics.

These conditions can be used as a starting point for applicants preparing a permit application under the BMO.

  1. Preamble (PDF, 50KB)
  2. Defendable space (PDF, 96KB)
  3. Access requirements (PDF, 1326KB)
  4. Water Supply (PDF, 170KB)
  5. Individual construction standard (PDF, 577KB)

BMO mandatory condition

Along with the CFA standard conditions, there is a mandatory BMO condition that must be included in every permit issued for buildings. This mandatory condition emphasises the ongoing implementation of bushfire protection measures listed in the permit.

Under this condition, the prescribed bushfire protection measures on your Bushfire Management Plan must be implemented and maintained on an ongoing basis. This mandatory condition can be found at Clause 44.06.05 of the planning scheme.

Tailoring requirements for an individual site

CFA regularly works with permit applicants and local councils to tailor an application to address certain aspects of a proposal. An application can be made to tailor requirements for an individual site.

The management of vegetation in the area of defendable space is the most commonly tailored condition.

Bushfire planning controls require vegetation management and water supply to meet planning scheme requirements under Clause 53.02, unless a schedule to the BMO states otherwise or CFA agrees to the change in writing.

How to prepare a tailored response

An application that proposes tailored bushfire protection measures must justify why an alternative proposal is being sought and how the tailored measures meet the objectives of the planning scheme.

The application must also demonstrate how and why the alternative proposal is appropriate given the:

  • likely bushfire behaviour and risk to the land
  • surrounding landscape
  • the proposed land use

CFA may apply site-specific conditions to a permit

There are situations where the standard requirements need to be modified due to the unique characteristics of a site. In such cases, CFA may apply site-specific conditions to its conditional approval.

There are a number of factors that CFA considers in the assessment of a proposed development that might contribute to CFA applying a site specific condition, including (but not limited to):

  • the location of the land
  • bushfire behaviour
  • surrounding topography
  • type of vegetation
  • landscape
  • access in and out of the site

CFA will use the bushfire hazard site assessment, bushfire hazard landscape assessment and bushfire management statement (BMS) to assess the individual requirements of a site. Conditions on a permit are based on the merits of the application and its individual characteristics.

Bushfire protection measures explained

Below, you can find more information about the five bushfire protection measures referred to in CFA's standard planning permit conditions.

The following information is designed to help:

  • landowners understand likely requirements before lodging a planning permit application
  • councils interpret referral responses and conditions
  • permit holders implement permit requirements.

Refer to the glossary to understand some of the terminology used within the conditions and information below.

1. Defendable space

A drawing that shows a house to the left and to the right of it an area labled Defendable space. In this area low shrubs have been removed and grass short, but larger trees remain. To the right of the defendable space is an area labled Hazard (unmanaged vegetation) which has bush in its natural state.
Defendable space creates separation between a house and nearby bush (unmanaged vegetation), to reduce the chance of the house being impacted by fire.

Developments in the BMO must have an area of land around the building where vegetation is modified and managed to reduce the effects of flame contact and radiant heat associated with a bushfire.

Defendable space creates a break between buildings and fuel for the fire

Providing an area of defendable space between a building and nearby vegetation, brush fencing or other flammable material can prevent flames reaching the building, reduce the effects of radiant heat and the intensity of an ember attack.

How to calculate defendable space

The area of defendable space required at the site will depend on the level of bushfire risk and the likely forms of bushfire attack. The factors influencing the level of bushfire risk include:

  • Environmental factors including fuel, topography and weather conditions
  • Site context, for example urban or remote location
  • Other bushfire mitigation measures incorporated into the design, such as the siting of the building and construction standard

A site assessment is required to calculate how much defendable space is required at a particular property. Refer to Clause 53.02 of the Planning Provisions for detailed requirements.

If you obtain a permit, the standard conditions are the starting point for the level of vegetation management in the defendable space. These requirements should be reflected on your Bushfire Management Plan.

Tailoring the defendable space requirements

If you want to tailor the requirements to suit your site, you will need to explain in your Bushfire Management Statement how you still meet the following objectives:

  • Maintain integrity of building to avoid compromising the building structure
  • Reduce the carry of surface fire (horizontal separation)
  • Reduce the carry of a canopy fire (horizontal separation)
  • Reduce fuel ladders (vertical separation)

Learn more about landscaping for bushfire and the principles of garden design which can slow the spread of fire and reduce the intensity of ember attack.

Download BMO defendable space (PDF 96kb)

2. Access

Fire truck attempting to drive through a property gate with fence post, retaining wall and bushes either side making access difficult.
Gate posts, bushes and structures too close to the driveway can prevent fire trucks from getting into your property in an emergency.

CFA may not be able to come to your property during a major fire, but if we do, our fire trucks must be able to safely enter and exit the property from the primary road network to reach the building or water supply. Access is also important to allow occupants of the building to get in and out safely in the event of an emergency.

The standard conditions include specifications relating to:

  • construction level
  • load limit
  • width
  • clearance
  • curvature
  • road grade
  • dips
  • turning circles
  • passing bays

If you obtain a permit, the standard conditions for access provide the minimum standards a fire truck needs to safely access your property. Refer to Clause 53.02 of the Planning Provisions for detailed requirements.

If you obtain a permit, the standard access conditions provide the minimum standards required for a fire truck to safely access your property. Refer to Clause 53.02 of the Planning Provisions for detailed requirements.

Download BMO Individual conditions Access (PDF 130.1KB)

3. Water supply

An above ground metal water tank with the compliant outlet located behind a house surrounded by bushland. The tank is located next to a gravel driveway with space for a fire truck to drive up next to the tank.
A static water supply in the BMO with a CFA-compatible outlet and excellent fire truck access.

There must be a static water supply available at all new developments for fire fighting purposes. The water supply must have appropriate volume, access and markings, and be compatible with CFA's fittings. It is also important that the water supply tank (and outlets) do not combust or melt during a fire event.

Why is a dedicated water supply important?

A dedicated water supply with appropriate volume, access and markings is crucial because:

  • reticulated water supplies may be compromised during major fire events, as was experienced in the Black Saturday fires
  • it can be used to defend against a bushfire if required.

How much water is required?

All new development must incorporate a static water supply for fire fighting purposes. The minimum volume of water supply will depend on whether it will be used by the land owner, occupant, or CFA.

CFA needs to be able to connect to the water supply in the event of a fire

An interactive illustration of a CFA compliant tank outlet. Red hotspots indicate more information about the illustration.

To enable the fire brigade to defend your property, it is critical that the CFA can easily access a suitable water source. This includes being able to connect CFA’s hoses onto your water tank and supply water to a fire truck when required. There must be a fitting which CFA can use and a separate connection which can be accessed by the owner or occupier of the property on the outlet of your water tank.

If specified within Table 2 to Clause 53.02-5 (if fire brigade access to your water supply is required), CFA’s standard BMO permit conditions require the pipe work, fittings and tank outlet to be a minimum size of 64mm.

65 mm BSP (British Standard Pipe) is the most common size available. A 65mm fitting is equivalent to the old 2.5 inch and a 65 mm BSP (2.5 inch) fitting exceeds CFA’s requirements, which complies with CFA’s standard permit conditions for the BMO.

The water supply must:

  • have outlets compatible with CFA’s fittings
  • be located near roads and buildings on the property
  • be identifiable, with a CFA water sign

CFA water signage and compliant tank outlets can be bought online.

Refer to Clause 53.02 of the Planning Provisions and the Department of Transport and Planning's website for further information about how much water is required and whether fire authority fittings are required.

Varying the standard water supply requirements

CFA may consider an alternative design for static water supply where volume, reliability, access and performance of a system are demonstrated to achieve equivalence to the standard requirements. However, we don't encourage this.

Dams and swimming pools are not suitable as an alternative static water supply due to the potential for reduced capacity and water quality in drought conditions (for example, through silting) .

Download BMO Individual Conditions Water Supply PDF (170kb)

4. Construction standards

An interactive diagram showing fire intensity increasing the closer a house is located to the bushfire hazard. A fire is on the right of image. Red hotspots provide more information when clicked.

The Bushfire Attack Level (BAL) increases as fire intensity and radiant heat (kilowatts per square metre) increases.

Building construction and design can be used to minimise the impact of ember attack and radiant heat on a building. Construction requirements for buildings are expressed as a Bushfire Attack Level (BAL) as prescribed in AS3959 or NASH Standard.

What is a Bushfire Attack Level?

A Bushfire Attack Level (BAL) is a way of measuring the ability of a building to withstand attack from bushfire. The form of bushfire attack and the severity will vary according to the conditions on the site.

There are six bushfire attack levels that form part of the Australian Standard for construction of buildings in bushfire prone areas (AS 3959):

  • BAL-LOW (never applied in any areas with BMO)
  • BAL-12.5
  • BAL-19
  • BAL-29
  • BAL-40
  • BAL-FZ (Flame Zone)

Determining the construction standard

To establish the appropriate construction standard for your development, you will need to conduct an assessment in accordance with Clause 53.02 of the planning scheme.

Learn more about BAL ratings.

Download BMO Individual Conditions Construction Standard (PDF 577kb)

BAL requirements are linked to the building system

The Building Code of Australia contains the overarching objectives and performance requirement in relation to achieving an appropriate construction standard to improve the ability of the building to withstand bushfire attack.

The National Construction Code (NCC) prescribes AS 3959-2018 Construction of buildings in bushfire prone areas and NASH 2021 Standard for steel framed construction in bushfire areas as a ‘deemed to satisfy’ response to overarching objectives and performance requirements. Alternatively, an applicant may prepare an alternative solution to achieve the same performance requirement (that is, not a ‘deemed to satisfy’ response).

Building design can also increase resilience to bushfire

In addition to the materials and construction standard of the building, the layout and design of a building can reduce the potential for debris (such as leaves) to accumulate and embers to enter the house.

Designs should avoid creating spaces where debris can accumulate, for example, complex roof designs.

The location of outbuildings should also be considered as they can act as a fuel source to the main building. Outbuildings should be located at least 10 metres from the main building.

Learn more about best practice design for building in Bushfire Prone Areas on CSIRO's website.

Contact CFA

If you have any questions relating to CFA's standard BMO permit conditions, contact CFA’s Fire Safety Team via email: firesafetyreferrals@cfa.vic.gov.au

 

Page last updated: Friday, 18 September 2026 9:16:47 AM

Other topics you may be interested in:

Planning and permits

CFA has a role in several aspects of the planning process in Victoria. Our role is to provide expert advice to councils and the Minister for Planning to ensure that new communities can be serviced by emergency services in the event of a fire. We also provide bushfire hazard advice to ensure that risks to life, property and infrastructure are considered as part of the planning process.

Tagged with Building, planning and regulations

Read article

Click through to Planning and permits

Radiant Heat

Radiant heat is extremely dangerous. It can kill you well before the flames from a bushfire reach you. Distance is always the best defence against radiant heat, but barriers can help. This page will help you understand more about radiant heat.

Tagged with Bushfire safety basics

Read article

Click through to Radiant Heat

Ember attack

Embers are the main way houses catch fire during a bushfire. Understand how embers spread fire and the importance of preparing your property so it can withstand an ember attack.

Tagged with Bushfire Safety basics

Read article

Click through to Ember attack